LimitLine

Learn · updated 2026-10-28

CUSUM Chart: Catch a Small, Lasting Shift

By Nicholas Williford, Lean Six Sigma Black Belt · About LimitLine

A CUSUM chart (cumulative sum chart) plots the running total of deviations from a target, so a small shift that lasts (0.5σ to 1σ) builds up into a signal much sooner than a single point would cross a Shewhart limit.

A Shewhart chart looks at each point on its own, so a lasting shift of half a standard deviation runs for about 155 points, on average, before one lands outside the limits. A CUSUM keeps a running total of how far the process sits above (or below) target, and that total grows quickly once the mean really moves.

Upper sumS_hi = max(0, previous S_hi + x − target − k)Lower sumS_lo = max(0, previous S_lo + target − x − k)Signaleither sum above the decision limit hUsual settingsk = 0.5σ, h = 4σ to 5σ (NIST's example uses h ≈ 6.6σ, from its V-mask design)

Worked Example (NIST)

Twenty group means, target 325, σ of the means 0.635. NIST uses k = 0.3175 (half a σ) and h = 4.1959. The upper sum stays near zero for 12 groups, then the mean moves up by about 3 and the sum climbs.

h 4.200Group 1: 0.00Group 2: 0.00Group 3: 0.00Group 4: 0.00Group 5: 0.03Group 6: 0.00Group 7: 0.00Group 8: 0.00Group 9: 0.00Group 10: 0.00Group 11: 0.00Group 12: 0.00Group 13: 3.01Group 14: 4.94 (Signal)Group 15: 7.45 (Signal)Group 16: 10.63 (Signal)Group 17: 11.99 (Signal)Group 18: 14.44 (Signal)Group 19: 16.00 (Signal)Group 20: 19.03 (Signal)15101420
Upper CUSUM of the NIST data. It crosses the decision limit at group 14 and keeps climbing: a lasting upward shift, not a one-off.
GroupMeanx − 325 − 0.3175Upper sum
12325.150-0.1680.00
13328.3253.0073.01
14327.2501.9334.94
15327.8252.5077.45

LimitLine's sums match the ones NIST prints for all 20 groups, and both signal first at group 14. The lower sum never gets near h: the process did not shift down.

Note that this shift is large (about 4σ of the means), so a plain Shewhart chart with limits 325 ± 3 × 0.635 would already flag group 13 (328.3, above 326.9). The NIST example shows how the sums work; CUSUM's real advantage is for small shifts of 0.5σ to 1σ, where a Shewhart chart takes dozens to hundreds of points.

Choosing K and H

CUSUM, EWMA or a Shewhart Chart?

For shifts of about 1.5σ or more, a Shewhart chart with the Nelson rules is enough and easier to explain. For small, lasting shifts (0.5σ to 1σ), a CUSUM or an EWMA chart catches them much sooner; the CUSUM also tells you when the shift started (where the sum left zero).

Run a CUSUM in LimitLineAdvanced control charts: EWMA, CUSUM and G charts (a Pro tool; Free users can try it on the example).

Sources

  1. NIST/SEMATECH e-Handbook, §6.3.2.3 CUSUM Control Charts
  2. D. C. Montgomery, Introduction to Statistical Quality Control, Wiley

The LimitLine Newsletter

About one email a month: new guides, tool updates and one practical SPC tip. Unsubscribe in one click.

We'll email you once to confirm before anything else is sent. Privacy